Resistant to concrete corrosion

Concrete is a relatively strong and sturdy building material but it can be severely impaired by poor manufacturing or in concrete corrosion.

Concrete degradation can be a major cause of damage to reinforced concrete structures, which leads to reduced protection for steel.

This results in steel corrosion, often followed by cracking and cracking of the concrete which can lead to structural damage.

Damage to concrete is caused by:
– Chemical decomposition
– Corrosion to reinforcement
– Mechanical attack

Destroyed concrete images

Protecting and waterproofing concrete by applying polyurea is a very common job. Thanks to the advantages of the seamless polymer elastomer, polyurea is effectively used for roofing, waterproofing the foundation, protecting tanks, floors, covering swimming pools and protecting any concrete structure.

Before applying polyurea to concrete, it is necessary to carry out some preparation activities. First of all, all dirt, defective and weak concrete surface should be removed from the surface. The cleaned concrete floor must be dry (no visible moisture, moisture not exceeding 8%). If there are large cavities, potholes and debris in the concrete, its surface should be filled.

Ứng dụng polyurea
Applying polyurea waterproofing the foundation

If the condition of the vertical surface is not satisfactory, a high-strength repair grout may be required prior to application of polyurea.

Its main purpose is to close relatively large voids present on the concrete surface. For high demands on decorative properties (eg, surface finishing of swimming pools), care should be taken to smooth out the plastering. The standard thickness of the polyurea coating is 1.5-3 mm. The application of polyureas can only conceal minor defects made during the preparation. After construction, the leveling and filling layers must be cured to a full ripeness and moisture content as indicated for use.

Ứng dụng polyurea
Pictures of waterproofing Polyurea on the roof

After the preparation work is completed, the plastering wall and the concrete surface of the floor must be primed one or more layers to increase the adhesion strength better and to overlap the voids. The primers, which penetrate the surface porosity, not only insulate the pores but also form a durable composite component that protects the applied polymer coating from the moisture of the substrate. One and two component inoculants based on epoxy and polyurethane resin, compatible with polyurea, can be used as a primer. The applied primer must be cured until fully cured according to the instructions. When applying polyurea without pre-priming or with incorrectly selected priming ingredients, potentially breaking the polymer’s adhesion and hardness. Air and moisture, voids of concrete or other porous substrates (plaster, cement, foam concrete, brick, wood) are displaced during the use of polyurea. This process leads to the formation of defects in the form of craters and even holes.

The application of polyurea is carried out on a concrete surface prepared according to the procedure described above, in one or several layers, depending on the required thickness. The specifications and service life of the protective coating depend directly on the correct compliance with the polyurea application technology and surface preparation.

Newtec is Vietnam’s leading company in concrete repair and protection, corrosion inhibition and structural enhancement. We can muster resources to support your complete project requirements, to manage corrosion. All are technically backed by the most experienced professionals in the industry.

Trả lời

Email của bạn sẽ không được hiển thị công khai. Các trường bắt buộc được đánh dấu *